Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/27/2002 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 08/01/2001 |
ROOF NAILING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO DRY IN ROOF 2) TRUSS MANUFACTERERS LETTER 12/20/00 MUST BE APPROVED AND ON FILE WITH CITY OF TUCSON PLAN CHECK |
| 11/27/2000 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/1. PLAN CALLS FOR 2 X 10 RAFTERS MAN MADE TRUSS JOISTS USED. PLAN MUST BE REVISED TO AS BUILT AND APPROVED BY PLAN CHECK. 2. TJI'S ARE WEATHER DAMAGED. REQUIRE TRUSS MANUFACTURE EVALUATION. 3. TJI HAVE ROOF SHEATHING NAILED WITH OVERSIZE NAILS. TRUSSES MUST BE EVALUATED AND APPROVED BY TRUSS MANUFACTURE. 4. YOU MUST PROVIDE TRUSS MANUFACTURES INSTALLATION INSTRUCTIONS. 5. TRUSSES MUST BE PROPERLY BLOCKED TO PREVENT TWISTING. 6. WEST TRUSS CANNOT BEAR ON 2 X 8IN FLAT. |
| 09/10/1999 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - OK MATER BEDROOM |
| 09/10/1999 |
ROOF NAILING |
|
Partial Approval |
PARTIAL APPROVAL |
| 09/08/1999 |
ROOF NAILING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 08/31/1999 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |