Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM03242
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/28/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - STPALES IN SHEARWALL TO STUDS MISSING STUD AT WESTSIDE OF ENTRY IN FRONT BEDROOM CLOSET 2ND STUD FROM CORNER GOING WEST, ATTACH SHEARWALL TO STUDS WITH PAHD AT MASTER BEDROOM AT WINDOW AND FRONT BEDROOM AT WINDOW. NAIL PAHD OVER OSB AFTER COMPLETING SHEAR. NOTE ON SHEET THIS ITEM OK DTW | |
10/13/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. NEED REVISED PLAN AT GARAGE SHOWING HOLD DOWNS FRAMING ETC. 2. PAHDS MISSING & PAHDS NEED TO BE NAILED TO DOUBLE FULL HEIGHT STUDS (NOT TRIMMERS) 3. CLIP CRIPPLES OVER HEADERS TO HEADERS. 4. CHECK ALL SHEAR PANELS FOR CORRECT NAILING AT STUDS, TOP PLATES, SHEAR BLOCKS AND SILL PLATE. MANY AREAS NOT NAILED. | |
10/13/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED |