Permit: T98CM03182

Parcel: 136083590


Addresses:

2530 S KEVIN DR

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
03/29/1999 FRAMING Correction Required ADDTL COMMS - 2 2. WHERE AND TO WHAT DRAIN LINE IS THE WASHER CONNECTED? 3. THE CLOTHES DRYER VENT- NEED TO INSTALL. CALL FOR AN ELECTRIC, PLUMBING, AND MECHANICAL INTERMEDIATE INSPECTION BEFORE DRYWALL.
03/24/1999 FRAMING Correction Required ADDTL COMMS - NEED FIRE BLOCKING AT DROP CEILING.
03/24/1999 FRAMING Partial Approval IVRS - Inspection 0000*
03/18/1999 FRAMING Correction Required ADDTL COMMS - 1. BLOCK AROUND DUCT (DEFUSERS). 2. FIRE BLOCK DROP CEILING.
03/18/1999 FRAMING Partial Approval IVRS - Inspection 0000*
01/08/1999 FRAMING Correction Required ADDTL COMMS - COMPLETE ALL TRADES THEN CALL FOR INSPECTION
01/08/1999 FRAMING Not ready for Inspection NOT READY FOR INSPECTION
11/06/1998 FRAMING Not ready for Inspection NOT READY FOR INSPECTION
10/20/1998 FRAMING Correction Required ADDTL COMMS - 1. INSTALL BANG PLATES AT STUDS WHERE WIRES RUN THROUGH CLOSE TO EDGES. 3. ROOF PITCH MIN 3/8 PER FOOT APPEARS TO BE INADEQUATE. 4. REVISED PLAN 2X6 AT 24 O.C.-PLAN CALLS FOR 2X8 AT 16 O.C. 5. RIDGE BEAM CANTILEVERS APPROX 6
10/20/1998 FRAMING Not ready for Inspection NOT READY FOR INSPECTION