Permit: T98CM03115

Parcel: 121031040


Addresses:

1855 N HART LN

Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/12/1998 BUILDING - FINAL Correction Required ADDTL COMMS - 1. INSTALL PLUG AT PANEL (ELECTRIC PANEL UNDERSIDE) 2. COMPLETE LABELING TO ELECTRIC CIRCUITS IN PANEL. 3. PROVIDE 90S AT CONDENSATE DRAINS. 4. COMPLETE INSTALLATION OF BATHROOM LIGHTING FIXTURES. 5. INSTALL ANIT TIP AT STOVE. 6. INSTALL DOUBLE FLUE COMPLETLY IN ATTIC . 7. REMOVE TAPE FROM DOUBLE WALL FLUE. 8. COMPLETE REAR HOUSE.
11/12/1998 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*