Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/19/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/08/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) BATHROOM FAN NOT IN 2) OK TO COMPLETE ALL BUT BATHROOM |
| 07/10/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK-TO DRYWALL ALL ROOM EXCEPT BATHROOM 2) PLUMBING NOT READY 3) INSTALL FANS |
| 07/03/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE 1" MINIMUM FOR FIRE STOP AT WALL 2) CONNECT ALL GROUND CLOCKWISE |
| 05/24/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MAKE UP ALL GROUNDS IN ELECTRIC BOXES 2) NAIL PROTECT ALL WIRES WITHIN 1 1/4" OF WALL SURFACE 3) WIRES MUST TERMINATE IN APPROVED BOXES 4) ELECTRIC OUTLETS REQUIRED WITHIN 6' OF DOOR WAYS AND 12' THERE AFTER AROUND ROOMS 5) ALL WALLS MUST BE FIRE STOPPED AT TOP PLATES 6) GROUND ALL METAL ELECTRIC BOXES |