Permit: T98CM02973

Parcel: 137060110


Addresses:

437 W NEBRASKA ST

Inspection Status: Correction Required

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
04/30/1999 BUILDING PRE-SLAB Correction Required ADDTL COMMS - THE PLUMBING DRAIN (ABS) PIPE HAS BEEN PROPERLY WRAPPED.
04/29/1999 BUILDING PRE-SLAB Correction Required ADDTL COMMS - YOU MUST WRAP THE ABS PIPE TO KEEP FROM CONTACT WITH CONCRETE.
04/29/1999 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*
04/23/1999 BUILDING PRE-SLAB Correction Required ADDTL COMMS - THE UNIFORM PLUMBING CODE (SECTION 313.2) REQUIRES THAT ALL ABS-AND OTHER PLASTIC PIPE BE WRAPPED TO PREVENT CONTACT WITH CONCRETE. WRAP THE PIPE WITH THIN FOAM OR CARD BOARD. RECALL THIS INEPCTION WHEN THIS HOUSE IS DONE. DO NOT POUR CONCRETE UNTIL THE ABOVE HAS BEEN DONE AND INSPECTED.
04/23/1999 BUILDING PRE-SLAB Denied IVRS - Inspection 0325*