Permit: T98CM02941

Parcel: 141180410

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
11/16/1998 FRAMING Correction Required ADDTL COMMS - ANCHOR DRYWALL NAILER ON EXT WALL NORTH SIDE
11/13/1998 FRAMING Correction Required ADDTL COMMS - ELEC NOT COMPLETE, FURNANCE VENT IN CONTACT WITH COMBUSTIBLE MATERIAL AT ROOF, A/C MECHANICAL DUCT RESTRICTED AT BEDROOM DIFFUSERS, DRYWALL NAILERS NOT INSTALLED AT BEDROOM CEILING, BATH EXHAUST DUCTS MUST EXHAUST OUTSIDE ALSO DAMAGED, PROTECT ALL PLBG FROM CHAFFING ON METAL STUDS, STOPPED INSP
11/13/1998 FRAMING Denied IVRS - Inspection 0999*