Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T98CM02883
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/29/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. DO NOT FORGET TO FIRE RATE 1 HR MATERIALS AT THE MANIBLOCK SYSTEM. 2. CHECK ALL PLUMBING LINE CLEARANCES FROM CAN LIGHTING OR HEAT SOURCES FOR MINIMUM 12. 3. ADDRESS 3 WCO AT 1ST FLOOR BATH. | |
10/22/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. CORRECT RIM JOIST THROUGHOUT. 2. ADD HARDWARE TO LANDING. 3. RECHECK AND WALK FRAMING RECHECK ALL FIREBLOCK! 4. CHECK ALL PLUMB CLEARANCES. | |
10/22/1998 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION | |
10/15/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. CONSULT WITH TRUSS ENGINEER ON TRUSSES MODIFIED TO FIT IN THE LR. 2. INSTALL POST UNDER BEARING TRUSS AT ENTRY. 3. REFER TO MFG REQUIRED SPECS FOR H2.5 CONNECTION TO TJI TYPE TRUSSES. 4. SHEAR TRANSFER AT INTERSECTING WALLS. 5. INSTALL BRACING PER TRUSS DRAWINGS. 6. PROVIDE TRUSS LAYOUT TO MATCH TRUSS DRAWINGS. 7. PROVIDE SPECIAL INSPECTION. 8. STOPPED INSPECTION. | |
10/15/1998 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION | |
10/12/1998 | FRAMING | Not ready for Inspection | NOT READY FOR INSPECTION |