Permit: T98CM02782


Addresses:

1494 W BREAKWELL ST

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/10/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - EXTERIOR OK. SEE INSPECTION REPORT OF 8/5/98 FOR INFORMATION REGARDING BAY WINDOW HEADERS. SIZES NOT TO PLAN
08/05/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. PLAN CALLS FOR 3 1/8 X 10 1/2 GLU LAM AT REAR NOOK . 4X10 BM USED. COMPLY WITH PLANS OR HAVE ARCHITECT OF RECORD MAKE CHANGE AND APPROVE AND HAVE C.O.T PLAN CHECK APPROVE. 2. HEADER AT BAY ON SIDE OF HOUSE TOO SMALL PER SCHEDULE 90 SPAN PLAN DOES NOT ADDRESS SIZE OF BM FOR THAT SPAN ONLY UP TO 50 HAVE ARCHITECT OF RECORD APPROVE SIZE OF BM AND C.O.T PLAN CHECK HAVE REVISIONS AT NEXT INSPECTION. 3. 2 ANCHOR MIN AT ENTRY COLUMN SILL AT BEARING BM. 4. NAIL ALL INTERSECTING WALLS AND CORNERS PER DETAIL 5/11. 12 O.C 16D. 5. STRAP TOP PLATES TO HEADER AT GARAGE 16 OC HEADER IS BEARING WALL.
08/05/1998 EXT METAL CLIPS/EXT SHEATHING Denied DENIED