Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/27/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - SEE REVISED DETAIL X-X SHOWS 3/2 X6 STUDS BETWEEN GLU-LAM & F/P HEADER - OK TO SHEETROCK EXCEPT ABOVE DETAIL |
| 01/27/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 01/20/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - INTERIOR GLU-LAM NOT PROPERLY SUPPORTED SEE DETAIL FOR CORRECT HARDWARE & POSTS/SUPPORTED BY HEADER AT FIREPLACE? (OK TO INSULATE) |
| 01/20/1999 |
FRAMING |
|
Denied |
DENIED |
| 01/04/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. INTERIOR GLU LAM NOT PROPERLY SUPPORTED SEE DETAIL FOR CORRECT HARDWARE AND POSTS/SUPPORTED BY HEADER AT FIRE PLACE?? 2. NEED H2.5S AT INTERIOR BEARING WALLS TO T J IS 3. MOVE WIRING AWAY FROM CAN LIGHTS. 4. NEED 1 CLEARANCE AT FURNACE W/H FLUE. 5. PLAN DOES NOT SHOW FURNACE AT GARAGE. |
| 01/04/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 12/01/1998 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |