Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/07/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - CHECK BOLTS ON HOLDDOWNS AT FINAL FRAME
12/01/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. COMPLETE ALL TRADES BEFORE YOU CALL FOR FRAMING INSPECTION. 2. CHECK ALL HD2A FOR MINIMUM 5/8 ANCHOR BOLT, SOME ARE USING 1/2 A.B AND TIGHTEN AS SHOWN ON FOUNDATION PLAN. 3. RECHECK AND NAIL BRACED WALL PANELS SOME AREAS LOOSE. 4. RECHECK ROOF SHEATHING FOR OVER DRIVEN STAPLES SOME AREAS APPEAR TO BE LOOSE. (CLEAN OFF DEBRIS).
12/01/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*