Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/07/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - CHECK BOLTS ON HOLDDOWNS AT FINAL FRAME |
| 12/01/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. COMPLETE ALL TRADES BEFORE YOU CALL FOR FRAMING INSPECTION. 2. CHECK ALL HD2A FOR MINIMUM 5/8 ANCHOR BOLT, SOME ARE USING 1/2 A.B AND TIGHTEN AS SHOWN ON FOUNDATION PLAN. 3. RECHECK AND NAIL BRACED WALL PANELS SOME AREAS LOOSE. 4. RECHECK ROOF SHEATHING FOR OVER DRIVEN STAPLES SOME AREAS APPEAR TO BE LOOSE. (CLEAN OFF DEBRIS). |
| 12/01/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |