Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/01/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - PENDING REVISED PLANS ON INSPECTION 11-24-98. MUST HAVE REVISIONS BY FINAL FRAME INSPECTION. |
| 11/30/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
CORRECTIONS INCOMPLETE |
| 11/27/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - OSB SHEAR PANELS MISSING AT ENTRY, CLIP ALL KING STUDS TO HEADERS |
| 11/27/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0000* |
| 11/25/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - SEE INSPECTION ON 11-19-98 RE-OSB SHEAR NOT NAILED. 1. CHECK ALL EDGE NAILING ON OSB SHEAR PANELS AND AT 8 BLOCKING. 2. CLIP ALL KING STUDS TO HEADERS AND CRIPPLES TO HEADERS. 3. DOUBLE STUD MIN UNDER 6X12 PORCH BM THAT POCKETS INTO EXT WALL. 4. OSB SHEAR PANELS MISSING AT ENTRY - SEE PLANS. 5. HAVE PLANS REVISE TO SPEC APPROVED TYPE HANGERS AT HIP RAFTERS TO LEDGER. |
| 11/25/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |
| 11/24/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. NEED FRONT ENTRY ROOF FRAMING REVISED BY ARCHITECT AND APPROVED BY PLAN CHECK. 2. LPI JOIST AT 45 DEGREE AT FRONT PORCH (ENTRY) NEED APPROVED SCREWED HANGERS. 3. REVISE PLAN TO SHOW HOLD DOWNS REQUIRED AND WHAT TYPE OF ALTERNATE IS TO BE USED INSTEAD OF PAHDS NOT INSTALLED. 4. NEED SPECIFIC DETAIL AT JACK RAFTER CONNECTION TO HIP THE WAY RAFTERS ARE TO BE CUT AND CONNECTED TO HIP AT REAR PORCH. 5. REVISE SHEAR NAILING TO SHOW USE OF STAPLES IN SHEAR PANELS OR USE 8D COMMONS PER APPROVED PLANS. 6. CLIP ALL HEADERS TO KING STUDS. |
| 11/24/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |
| 11/19/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. ANCHOR BOLTS, NUT AND WASHER INCOMPLETE ALL WALLS. 2. PARAPET FIREBLOCKING PER DETIALS 9 AND 10 OF DETAIL SHEET MISSING AT SOME WALLS. 3. PAHD (OR EQUIVELANT) HOLD DOWNS MISSING ALL LOCATIONS. SOME OSB PANELS NEED NAILING. CORRECT AND RECALL. |
| 11/19/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |
| 11/18/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - NO PLANS/PERMIT ON SITE |
| 11/18/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |