Permit: T98CM02354

Parcel: 116274840


Addresses:

3444 W TINY BIRD CT

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/01/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - PENDING REVISED PLANS ON INSPECTION 11-24-98. MUST HAVE REVISIONS BY FINAL FRAME INSPECTION.
11/30/1998 EXT METAL CLIPS/EXT SHEATHING Denied CORRECTIONS INCOMPLETE
11/27/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - OSB SHEAR PANELS MISSING AT ENTRY, CLIP ALL KING STUDS TO HEADERS
11/27/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0000*
11/25/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - SEE INSPECTION ON 11-19-98 RE-OSB SHEAR NOT NAILED. 1. CHECK ALL EDGE NAILING ON OSB SHEAR PANELS AND AT 8 BLOCKING. 2. CLIP ALL KING STUDS TO HEADERS AND CRIPPLES TO HEADERS. 3. DOUBLE STUD MIN UNDER 6X12 PORCH BM THAT POCKETS INTO EXT WALL. 4. OSB SHEAR PANELS MISSING AT ENTRY - SEE PLANS. 5. HAVE PLANS REVISE TO SPEC APPROVED TYPE HANGERS AT HIP RAFTERS TO LEDGER.
11/25/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
11/24/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. NEED FRONT ENTRY ROOF FRAMING REVISED BY ARCHITECT AND APPROVED BY PLAN CHECK. 2. LPI JOIST AT 45 DEGREE AT FRONT PORCH (ENTRY) NEED APPROVED SCREWED HANGERS. 3. REVISE PLAN TO SHOW HOLD DOWNS REQUIRED AND WHAT TYPE OF ALTERNATE IS TO BE USED INSTEAD OF PAHDS NOT INSTALLED. 4. NEED SPECIFIC DETAIL AT JACK RAFTER CONNECTION TO HIP THE WAY RAFTERS ARE TO BE CUT AND CONNECTED TO HIP AT REAR PORCH. 5. REVISE SHEAR NAILING TO SHOW USE OF STAPLES IN SHEAR PANELS OR USE 8D COMMONS PER APPROVED PLANS. 6. CLIP ALL HEADERS TO KING STUDS.
11/24/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
11/19/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. ANCHOR BOLTS, NUT AND WASHER INCOMPLETE ALL WALLS. 2. PARAPET FIREBLOCKING PER DETIALS 9 AND 10 OF DETAIL SHEET MISSING AT SOME WALLS. 3. PAHD (OR EQUIVELANT) HOLD DOWNS MISSING ALL LOCATIONS. SOME OSB PANELS NEED NAILING. CORRECT AND RECALL.
11/19/1998 EXT METAL CLIPS/EXT SHEATHING Denied DENIED
11/18/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - NO PLANS/PERMIT ON SITE
11/18/1998 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*