Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/11/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - PER DAVE WILLETTS REQUEST AND LETTER IN RESPONSE HAVE DEVELOPMENT SERVICES CENTER STAMP COPY |
| 09/08/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. ROOF FRAMING PLAN NEEDS TO BE APPROVED AND STAMPED BY CITY PLAN CHECK RAFTER A-4 AND A-8 SPECS MISSING. 2. HAVE ARCHITECT OF RECORD ADDRESS HOLD DOWNS MISSING AT BAY WINDOW RE: WHAT KIND OF ALTERNATE HOLD DOWN ATTACHMENT TO STUDS AND IF DOUBLE FULL LENGTH STUDS ARE REQUIRED OR NOT. NEEDS TO BE STAMPED AND APPROVED BY CITY PLAN CHECK AND ARCHITECT. |
| 09/08/1998 |
FRAMING |
|
Partial Approval |
PARTIAL APPROVAL |
| 09/04/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NEED COMPLETE ROOF FRAMING SPECS. 2. DOUBLE FULL LENGTH STUDS AT HOLD DOWNS AT BAY WINDOW REQUIRED. |
| 09/04/1998 |
FRAMING |
|
Partial Approval |
PARTIAL APPROVAL |
| 09/03/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. PLANS CALL FOR DOUBLE RAFTER IN GARAGE NEAR ENTRY SIDE. 2. DOUBLE 2X6 HEADER AT DOOR FROM GARGE INTO HOUSE NEED TO BE ON EDGE. NO FLAT. 3. GARAGE INTERIOR WALL IS A SHEAR WALL SHEAR NEEDS TO BE TRANSFERED DOUBLE TOP PLATES OF WALL DROP IS IN THE WAY. USE OSB OR 5/8 DRY WALL ABOVE DROP TO TOP PLATES AND NAIL PER SHEAR SCHEDULE. 4. FIRE BLOCK MISSING AT SOUTH EAST CORNER OF GARGE AT CEILING. STOPPED FRAMING INSPECTION HAVE BUILDER CHECK HOUSE BEFORE RECALLING INSPECTION . NEED REVISED ROOF FRAMING PLAN FROM 2X12S TO I JOIST TYPE RAFTERS NEED TO BE STAMPED BY CITY PLAN CHECK ALSO. |
| 09/03/1998 |
FRAMING |
|
Denied |
DENIED |