Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T98CM02099
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/11/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. INSTALL SPARK PROTECTION AT HEARTH EXTENSION. 2. NUTS AND WASHERS MISSING IN GARAGE CHECK ALL PLATES. 3. H2O NOT CONNECTED NO H2O PRESSURE TEST. 4. INSULATE ALL DUCT METAL JOINTS. 5. FRONT ENTRY COL.3 PIECES NEED ANCHOR TO STEM AND AT TOP. 6. REAR 4X4 NOT STRAPPED TO DIAGONAL BEAM, ADD ONE STRAP EACH LOCATION ALL POSTS. 7. AT REAR SLIDING DOOR P.A. STRAP NOT ATTACHED. |