Permit: T98CM01914

Parcel: 137323270


Addresses:

5540 S WEMBLY RD

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
07/31/1998 FRAMING Correction Required ADDTL COMMS - HAVE DUCTS IN GARAGE BLOCKED. HAVE FAN BOXES RESCREWED TO NEW BLOCKS
07/30/1998 FRAMING Correction Required ADDTL COMMS - PLEASE CORRECT THE FOLLOWING AND RECALL INSPECTION. 1. REMOVE ALL NAILS INTO SIDES OF TJI TRUSSES. 2. REMOVE ELECTRICL BOX SCREWED INTO TRUSS CORD AT MASTER BEDROOLM ADD BLOCK AND ATTACH BOX. 3. DO NOT ALLOW ANY NAILING INTO TOP OR BOTTOM CORDS OF TJI TRUSSES AS THIS CAUSES SEPARATION OF THE PLIES. REFER TO MANUFACTURERS CATALOG FOR INSTRUCTIONS.
07/30/1998 FRAMING Denied DENIED