Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/12/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. SUPPORT ALL EDGES OF SHEAR WALL 7 AND NAIL ALL SUPPORTING EDGES OF TIGHT WITH FRAME. 2. H2.5 CLIPS REQUIRED AT EACH TRUSS AT SHEAR WALL 7 SEE 4/A8 ALSO STUDS TO DOUBLE TOP PLATE. 3. BLOCK DEFUSERS 3 SIDES. 4. DEAD WOOD NOT ATTACHED TO WALLS IN HALL. 5. NON BEARING WALL STUD CUT GREATER THAN 60% AT RANGE. 6. PROVIDE APPROVED REPAIR DOCUMENTS FOR THREE TRUSSES NOT ON 3 PT BEARING. |
| 06/12/1998 |
FRAMING |
|
Denied |
DENIED |
| 06/04/1998 |
FRAMING |
|
Denied |
DENIED |