Permit: T98CM01681

Parcel: 131020850


Addresses:

5301 E 26TH ST

Inspection Status: Correction Required

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/24/1998 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. GAS PRESSURE TEST WAS TO BE LEFT ON. 2. AT FINAL PUT SYSTEM UNDER PRESSURE WITH A GAUGE FOR PRESSURE TEST. 3. OLD BATHROOM NEEDS AN EXHAUST FAN WILL CHECK AT FINAL.
08/14/1998 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. SEE UNIFORM PLUMBING CODE SECTION 1211.10. 2. USE RIGHT HAND / LEFT COUPLING ( LOUS PLUMBING) TO CONNECT NEW PIPE TO EXISTING LEAVE SHEET ROCK OPEN AN THAT CONNECTION TO VERIFY COUPLING.
08/14/1998 PLUMBING - INTERMEDIATE Not ready for Inspection NOT READY FOR INSPECTION
08/03/1998 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. USE RIGHT HAND/ LEFT COUPLING ( LOUS PLUMBING) TO CONNECT NEW PIPE TO EXISTING LEAVE SHEETROCK OPEN AN THAT CONNECTION TO VERIFY COUPLING. 2. BLOCK EACH SIDE OF VENT . 3. GROUNDING ELECTRIC RODE CONDUCTOR TO BE ONE PIECE OF WIRE OR CAP WELD .
08/03/1998 PLUMBING - INTERMEDIATE Partial Approval PARTIAL APPROVAL
07/20/1998 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. 3/4 METAL PIPE GAS OR H2O NOT ALLOWED UNDER SLAB. 2. PROTECT ALL PLUMBING FROM SHEET ROCK NAILS.
07/20/1998 PLUMBING - INTERMEDIATE Not ready for Inspection NOT READY FOR INSPECTION