Inspection Status: Correction Required
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/14/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. MUST HAVE C.O. FOR KITCHEN SINK ON VERTICAL NOT HORIZONTAL. 2. MUST HAVE 2 P-TRAP FOR 2 DIRTY ARM. P-TRAP MUST BE THE SAME SIZE AS DRAIN SERVED. |
| 03/14/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0000* |
| 03/04/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. UNIT #2 WASTE AND VENT SYSTEM OK 2. UNIT #2 WATER DISTRIBUTION OK 3. UNIT #2 OK TO DRYWALL 4. UNIT # 1&3 ROUGH PLDG AND INTERMEDIATE DENIED MUST HAVE 2 WASTE LINE FOR KIT SINK 5. NOTE: YOU CAN ONLY WET VENT 2 FIXTURE UNITS ON A VERTICAL WET VENT 6. EXSISTING WATER CLOSET MUST HAVE MIN 2 VTR |
| 03/04/2000 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |
| 02/09/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0000* |
| 07/23/1999 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. UNIT 1 WAS LOCKED |
| 07/23/1999 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0000* |