Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM01639
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/14/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - REGARDING : THE 3 5/8 WIDE GLU-LAM HEADER DO NOT MEET THE REQUIREMENT OF UBC 2326 11.2 REQUIRING WALL STUDS HAVE FULL BEARING ON A SILL PLATE ETC OF THE SAME WIDTH. THE WALL STUDS ARE 2X6. | |
07/13/1998 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | SEE #1  PREVIOUS INSP | |
07/08/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. PLANS CALL FOR 5 1/8 X 9 GLU LAM AT FAMILY ROOM WINDOW AND KITCHEN DOOR/ NOOK. BM MISSING AT NOOK AND 3 1/8X11 2/8 GLU LAM USED AT WINDOW. COMPLY WITH PLANS OR HAVE ARCHITECT OF RECORD APPROVE CHANGES. 2. SEE A3/1 FOR DECK DETAIL TO HOUSE AND COMPLY OR HAVE ARCHITECT OF RECORD APPROVE CHANGES. 3. PROVIDE POST UNDER GLU LAM BM AT GARAGE SOUTH SIDE CLIP CRIPPLES ABOVE HEADER AT 32 O.C | |
07/08/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED | |
07/06/1998 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | NOT READY FOR INSPECTION |