Permit: T98CM01639

Parcel: 133051640

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T98CM01639

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
07/14/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - REGARDING : THE 3 5/8 WIDE GLU-LAM HEADER DO NOT MEET THE REQUIREMENT OF UBC 2326 11.2 REQUIRING WALL STUDS HAVE FULL BEARING ON A SILL PLATE ETC OF THE SAME WIDTH. THE WALL STUDS ARE 2X6.
07/13/1998 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection SEE #1 &#2 PREVIOUS INSP
07/08/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. PLANS CALL FOR 5 1/8 X 9 GLU LAM AT FAMILY ROOM WINDOW AND KITCHEN DOOR/ NOOK. BM MISSING AT NOOK AND 3 1/8X11 2/8 GLU LAM USED AT WINDOW. COMPLY WITH PLANS OR HAVE ARCHITECT OF RECORD APPROVE CHANGES. 2. SEE A3/1 FOR DECK DETAIL TO HOUSE AND COMPLY OR HAVE ARCHITECT OF RECORD APPROVE CHANGES. 3. PROVIDE POST UNDER GLU LAM BM AT GARAGE SOUTH SIDE CLIP CRIPPLES ABOVE HEADER AT 32 O.C
07/08/1998 EXT METAL CLIPS/EXT SHEATHING Denied DENIED
07/06/1998 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection NOT READY FOR INSPECTION