Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/01/1999 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 1. WINDOW AT ENTRY IS REQUIRED TO BE TEMPERED SAFTEY GLASS WITHIN 2 OF DOOR LATCH OR HINGE. COULDNT LOCATE PERMANENT MARKING. |
| 02/01/1999 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 12/30/1998 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - PROVIDE NO LUX FOR ALUMINUM CONDUCTOR TO BUSS BAR, PROVIDE BREAKER FOR IRRIGATION - ELEC PANEL NOT APPROVED FOR DOUBLE LUG BREAKERS, PROVIDE TEMPERED GLASS 2 FROM ANY DOOR LATCH OR HINGE, INSTALL ANTI-TIP FOR STOVE, INSTALL DIFUSSER/BEDROOM, INSTALL AIR ADMITTANCE VALVE |
| 12/30/1998 |
BUILDING - FINAL |
|
Denied |
DENIED |