Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/06/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 02/07/2001 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. NEED GFC IN GARAGE. 2. BOND ALL METAL BOXES. 3. PROTECT ENDS OF CONDUIT FROM WIRE. 4. RUN CONDUIT INTO BOX FOR LIGHTS. 5. DRYER/RANGE 4 WIRES EACH HOME RUN. 6. THHN SINGLE STRAND NEEDS TO BE IN CONDUIT. 7. ALL J-BOX HAVE TO BE ACCESSIBLE 8. HOT NEUTRALS REVERSED. 9. ROMEX IN LAUNDRY TO BE PROTECTED. |
| 02/05/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/1. NEED TO SEE BOTH ENDS OF YOUR CIRCUITS, ON ONE HOME 2. NEED ROMEX CONNECTORS AND BUSHINGS AT ALL METAL BOXES. 3. SUB-PANEL AND RANGE REQ. 4 WIRE CABLE, 2 HOT, NEUTRAL AND GROUND. 4. CAN'T RUN AWG SINGLE WIRE IF NOT IN CONDUIT. 5. ALL METAL BOXES NEED A BONDING JUMPER AND GREEN GROUND SCREW. 6. GARAGE OUTLETS TOO BE GFCI PROTECTED. 7. ALL WIRE TOO BE PROTECTED TO CEILING HT. 8. HOT AND NEUTRALS REVERSED IN GARAGE OUTLETS DON'T USE THEM. |