Permit: T98CM01407

Parcel: 111041940


Addresses:

3346 N EDITH BL

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
01/26/1999 FRAMING Correction Required ADDTL COMMS - 1. METAL BOXES NEED TO BE GROUNDED. 2. CLOSET LIGHTS TO BE 12 IN FRONT OF SHELVING. 3. REINFORCE CELING JOIST. 4. LEVEL OUT WASTE LINE FOR VANITY. 5. DRYER NEEDS VENTED OUTSIDE. 6. FLUES AND WASTE VENTS WITHIN 10 OF COOLER NEED TO BE 1 ABOVE AIR IN TAKE. 7. COOLER NOT WIRED PROPERLY. 8. NAILERS MISSING. 9. LIGHT IN BATH IN WET LOCATION. 10. SOFFITS NOT COMPLETE. 11. GLAZING WITHIN 2 OF DOORWAY NEEDS TO BE TEMPERED. 12. J BOX IS OVER LOADED IN LAUNDRY. 13. IMPROPER FLUE PIPE CONNECTION ON HOT WATER HEATER.
01/26/1999 FRAMING Denied IVRS - Inspection 0999*
10/06/1998 FRAMING Not ready for Inspection COMPLETE ALL TRADES