Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/26/1999 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. METAL BOXES NEED TO BE GROUNDED. 2. CLOSET LIGHTS TO BE 12 IN FRONT OF SHELVING. 3. REINFORCE CELING JOIST. 4. LEVEL OUT WASTE LINE FOR VANITY. 5. DRYER NEEDS VENTED OUTSIDE. 6. FLUES AND WASTE VENTS WITHIN 10 OF COOLER NEED TO BE 1 ABOVE AIR IN TAKE. 7. COOLER NOT WIRED PROPERLY. 8. NAILERS MISSING. 9. LIGHT IN BATH IN WET LOCATION. 10. SOFFITS NOT COMPLETE. 11. GLAZING WITHIN 2 OF DOORWAY NEEDS TO BE TEMPERED. 12. J BOX IS OVER LOADED IN LAUNDRY. 13. IMPROPER FLUE PIPE CONNECTION ON HOT WATER HEATER. |
| 01/26/1999 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 10/06/1998 |
FRAMING |
|
Not ready for Inspection |
COMPLETE ALL TRADES |