Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T98CM01368
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/24/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. STRAP TOP PLATE BOTH SIDES DRYER DUCT. 2. WEST WALL EXHAUST FAN DUCT. 3. SECURE H2O LINES GARAGE. 4. BLOCK AT PLENIUM. 5. X BRACING CUT KITCHEN. 6. PLATE AT 8# VENT WEST WALL. 7. PLENIUM BOTH ENDS S/ NORTH. | |
06/22/1998 | FRAMING | Correction Required | ADDTL COMMS - PROVIDE AND CORRECT: 1. FULL POST UNDER EACH END OF GIRDER TRUSSES. 2. POST TO BEAM POSITIVE CONNECTION ALL BEAM ENDS. 3. BLOCK REGISTERS A/C. PROVIDE ENGINNERING DETAIL FOR SHEAR WALL POST TO BEAM CONNECTION AND SHEAR WALL LOCATIONS. | |
06/22/1998 | FRAMING | Denied | DENIED |