Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. STRAP TOP PLATE BOTH SIDES DRYER DUCT. 2. WEST WALL EXHAUST FAN DUCT. 3. SECURE H2O LINES GARAGE. 4. BLOCK AT PLENIUM. 5. X BRACING CUT KITCHEN. 6. PLATE AT 8# VENT WEST WALL. 7. PLENIUM BOTH ENDS S/ NORTH. |
| 06/22/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - PROVIDE AND CORRECT: 1. FULL POST UNDER EACH END OF GIRDER TRUSSES. 2. POST TO BEAM POSITIVE CONNECTION ALL BEAM ENDS. 3. BLOCK REGISTERS A/C. PROVIDE ENGINNERING DETAIL FOR SHEAR WALL POST TO BEAM CONNECTION AND SHEAR WALL LOCATIONS. |
| 06/22/1998 |
FRAMING |
|
Denied |
DENIED |