Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. STRAP TOP PLATE BOTH SIDES DRYER DUCT. 2. WEST WALL EXHAUST FAN DUCT. 3. SECURE H2O LINES GARAGE. 4. BLOCK AT PLENIUM. 5. X BRACING CUT KITCHEN. 6. PLATE AT 8# VENT WEST WALL. 7. PLENIUM BOTH ENDS S/ NORTH. |
| 06/22/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - PROVIDE AND CORRECT: 1. FULL POST UNDER EACH END OF GIRDER TRUSSES. 2. POST TO BEAM POSITIVE CONNECTION ALL BEAM ENDS. 3. BLOCK REGISTERS A/C. PROVIDE ENGINNERING DETAIL FOR SHEAR WALL POST TO BEAM CONNECTION AND SHEAR WALL LOCATIONS. |
| 06/22/1998 |
FRAMING |
|
Denied |
DENIED |