Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/04/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. SHEAR PANEL MISSING AT END OF KIT WALL WILL CHECK AT FINAL FRAME. |
| 06/02/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |
| 06/01/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 05/28/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. CHECK CLIPS AT FRONT BATH ROOM WALL STUDS. 2. SHEAR PANELS MISSING. |
| 05/28/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |
| 05/27/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 05/26/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. SHEAR PANELS NOT NAILED TO ROOF SHEATHING. BLOCK AT TOP OF SHEAR BLOCKING NEEDS TO BE FLUSH WITH UNDER SIDE OF ROOF SHEATHING (SAME ANGLE) AND NAILED THRU SHEATHING TO BLOCKING. 2. NAIL BIRD BDS AT ROOF SHEATHING. 3. CHECK FOR MISSING H2.5 OR RSP4S AT STUD TO PLATES AT TOP AND BOTTOM. 4. PAHD AT REAR SHEAR IN WRONG LOCATION USE ALT HOLD DOWN. |
| 05/26/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |