Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM01103
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/13/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. PAHD AT LEFT OF ENTRY DOOR IN WRONG LOCATION USE ALT HD. 2. C.C. POST TO BEAM CAPS AT GARAGE DOOR HEADER REQUIRED SEE PLANS. WILL CHECK ABOVE MENTIONED AT FINAL FRAME. | |
05/07/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. A-35 MISSING AT PORCH LEDGER. 2. MISSING 4X6 POST W/SIMP. PCH6 AT PORCH. 3. PA STRAP LFT FRONT ON ONLY 1 STUD USE ALTERNATE FRAMING. 4. STRAP PARAPIT AT CORNER OF OPT FAMILY ROOM SOUTH SIDE. 5. 2 ANCHOR BOLTS FRONT COLUMNS. 6. USE ALTERNETE AT SHEAR WALL (ENTRY). 7. COUPLE BLOCKS MISSING ON SHEAR WALL AT ENTRY AND FRONT. 8. STRAP HEADERS AT ENTRY BY COLUMNS. 9. ROOF IS COMPLETELY COVERED IN LOOSE NAILS AND DEBRIS CANT INSEPCT. 10. POST CAPS AND STRAPS AT GARAGE OPENING. | |
05/07/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED | |
05/06/1998 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | NOT READY FOR INSPECTION | |
04/29/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED |