Permit: T98CM00874

Parcel: 11604071A


Addresses:

1841 N WESTRIDGE AV

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/12/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. INSTALL T.C CLIPS ON TRUSSES AT FRONT PORCH AND OVER ENTRY DOOR ( STUBBED END TRUSSES) WILL CHECK AT FINAL FRAME. 2. INSTALL H2.5 FROM TRUSSES TO TOP PLATE AT ENTRY ROOF TRUSSES WILL CHECK AT FINAL FRAME.
10/01/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. CLIP HEADERS TO KING STUDS AT BAY WINDOW AND STUDS TO PLATE ( TOP AD BOTTOM). 2. CLIP ALL EXTERIOR WALL STUDS TO SILL PLATES AND TOP PLATES ( AT GABLE ENDS ETC). 3. PROVIDE TRUSS CLACS AND LAYOUT. 4. HAVE CITY PLAN CHECK AND ARCHITECT OF RECORD ADDRESS METHOD OF ATTACHING PORCH BEAM AT REAR TO MASONARY WALL AT BEAM POCKETS. PA18 INSTALLED MUST BE NAILED TO SIDE OF BEAM NOT BOTTOM.
10/01/1998 EXT METAL CLIPS/EXT SHEATHING Denied DENIED