Permit: T98CM00759

Parcel: 13308010G


Addresses:

8150 E SENECA ST

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/31/2000 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. WEB STIFFENERS ARE MISSING ON TJIS. 2. VENT HOLES ARE MISSING AT ROOF. 3. FIRE BLOCK LL DROPPED CEILING AREAS MUST SUPPORT 2X6 DROPPED CEILING FROM JFIS AND INSTALL JOIST HANGERS AT ALL ENDS. 4. ANCHOR FLUE PIPING. 5. NEED VERIFICATION 2-A35S LEDGER TO STUD (SPAN OVER 20). 6. MAINTAIN NAILING PATTERN. 6. MAINTAIN NAILING PATTERN. SHEAR WALLS AND ROOF SHEATHING. 7. MINIMUM 10 LB TEST GAS PIPING.
01/31/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
01/27/2000 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. WEB STIFFENERS TJI AT BEARING. 2. NEED DETAIL ON 2 X 6 DROPPED CEILING. 3. FIRE BLOCK ALL FURRDOWN AREAS, POSITIVE CONNECTORS. 4. ANCHOR FLUE PIPES MINIMUM 1 FROM WOOD. 5. 2-A35S EDGE TO STUD OVER 20 SPAN. 6. 2-3 DIAMETER HOLES EACH RAFTER SPACE THROUGH SHEATHING. 7. INSTALL MISSING HOLD DOWNS. 8. MAINTAIN MINIMUM NAILING PATTERN OF SHEATHING AND S.WS.
01/27/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
01/24/2000 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 2. 6 & 12 NAILING PATTERN NOT CORRECT. 3. FIRE BLOCK, FIREPLACE INCORRECTLY INSTALLED. 4. NO H20 PRESSURE TEST PLUMBING. 5. SHEAR NOT NAILED OFF PER SCHEDULE. 6. EXTERIOR PAS MISSING. 7. STOPPED INSPECTION. COMPLETE ALL TRADES. RE-CALL WHEN READY.
01/24/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
11/12/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - CLIPS ON HEADER LEDGER OK TO FINISH, FINISH SHEATHIN.
11/12/1999 EXT METAL CLIPS/EXT SHEATHING Partial Approval PARTIAL APPROVAL