Permit: T98CM00750

Parcel: 114466790

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T98CM00750

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
04/17/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. MISSING NAILING AT FRONT ENTRY ROOF ALSO AROUND CHIMNEY CHASE,CHASE NEEDS TO BE. 2. CHIMNEY CHASE MISSING CRICKET NOT BUILT PER DETAIL DRAWING INSTALL 2 2X4 3. HEADER IN REAR 8050 WINDOW CALLS FOR 2 2X6 LOOKS LIKE MIGHT BE TOO SMALL? 4. ADD SCAB TO TRUSS MARKED ON FLOOR FRONT BEDROOM