Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM00750
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/17/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. MISSING NAILING AT FRONT ENTRY ROOF ALSO AROUND CHIMNEY CHASE,CHASE NEEDS TO BE. 2. CHIMNEY CHASE MISSING CRICKET NOT BUILT PER DETAIL DRAWING INSTALL 2 2X4 3. HEADER IN REAR 8050 WINDOW CALLS FOR 2 2X6 LOOKS LIKE MIGHT BE TOO SMALL? 4. ADD SCAB TO TRUSS MARKED ON FLOOR FRONT BEDROOM |