Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/17/1998 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. MISSING NAILING AT FRONT ENTRY ROOF ALSO AROUND CHIMNEY CHASE,CHASE NEEDS TO BE. 2. CHIMNEY CHASE MISSING CRICKET NOT BUILT PER DETAIL DRAWING INSTALL 2 2X4 3. HEADER IN REAR 8050 WINDOW CALLS FOR 2 2X6 LOOKS LIKE MIGHT BE TOO SMALL? 4. ADD SCAB TO TRUSS MARKED ON FLOOR FRONT BEDROOM |