Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM00715
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
05/06/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - GABLE END STRUCTURE NEED WEDGE/FILLER AND NAIL ROOF SHEATHING TO SAME. SUBMIT REVISION FOR DEPARTURE OF ROOF RAFTER SIZE. SUBMIT DETAIL OF ATTACHMENT OF INTERIOR CIELING STRUCTURE TO ROOF RAFTERS. RECALL WHEN CORRECTED. EXTERIOR A2.5 CLIPS MISAPPLIED. ONCE FLATTENED (INWARD OR OUTWARD) THE PRODUCT LOOSES ITS LISTING USE FLAT STRAP OR ? OTHER MATERIAL. | |
05/06/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED |