Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T98CM00628

Parcel: 118072490

Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/29/1998 BUILDING - FINAL Correction Required ADDTL COMMS - 3. DRYER GAS LINE NEEDS GAS COCK INSTALLED WITH FLEX AND CAPPED OFF. 4. NEED SPECS ON WATER HEATER RE: CLEARANCES TO COMBUSTIBLES WATER HEATER APPEARS TO BE TO CLOSE TO COMBUSTIBLES. 5. NEED STUCCO CERT. 6. WATER BOND FROM COLD WATER LINE TO MAIN PANEL REQUIRED IF WATER PIPING IS COPPER. IF PLUMBED IN PLASTIC PIPE THEN MARK MAIN ELECT PANEL INSIDE PLUMBED IN PLASTIC PIPE.
12/29/1998 BUILDING - FINAL Denied DENIED
12/16/1998 BUILDING - FINAL Correction Required ADDTL COMMS - ADD ANTI-SIPHON DEVICES TO EXTERIOR HOSE BIBBS RECALL WHEN DOOR IS OPEN.
12/16/1998 BUILDING - FINAL Denied IVRS - Inspection 0920*