Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/29/1998 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 3. DRYER GAS LINE NEEDS GAS COCK INSTALLED WITH FLEX AND CAPPED OFF. 4. NEED SPECS ON WATER HEATER RE: CLEARANCES TO COMBUSTIBLES WATER HEATER APPEARS TO BE TO CLOSE TO COMBUSTIBLES. 5. NEED STUCCO CERT. 6. WATER BOND FROM COLD WATER LINE TO MAIN PANEL REQUIRED IF WATER PIPING IS COPPER. IF PLUMBED IN PLASTIC PIPE THEN MARK MAIN ELECT PANEL INSIDE PLUMBED IN PLASTIC PIPE. |
| 12/29/1998 |
BUILDING - FINAL |
|
Denied |
DENIED |
| 12/16/1998 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - ADD ANTI-SIPHON DEVICES TO EXTERIOR HOSE BIBBS RECALL WHEN DOOR IS OPEN. |
| 12/16/1998 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0920* |