Permit: T98CM00506

Parcel: 111050330

Inspection Status: Correction Required

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/05/1999 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. ALL CORRECTIONS HAVE BEEN MADE 2. OK TO DRYWALL
08/03/1999 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. COUPLING @ LAUNDRY RM MUST BE SPECIALTY COUPLING OR ABS COUP NOT NO HUB COUPLING 2. UNIT # 2 GAS PRESSURE TEST UNDER 10 LBS
08/03/1999 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*
07/28/1999 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. C.O. THAT EXTENDS TO OUTSIDE OF BLDG MUST HAVE DIRECTIONAL FITTING 2. GAS LINE DRAWING SHOWS 3/4 LINE FOR RANGE. PUT IN 3/4 OR GET PLAN CHANGE TO 1/2 3. NO ROOF JACKS FOR GAS LINE PENETRATIONS THRU ROOF
07/28/1999 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*