Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM00486
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/18/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - CHECK MTT 28 ON NORTH SIDE OF GARAGE OPENING AT FINAL FRAME. | |
03/17/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. ANCHOR SILL PLATE W/RH BOLT AT ENTRY COLUMN. THE ONE HOLDING HEADER UP. 2. STRAP GABLE END TRUSS AT ENTRY COLUMN TO STUDS BELOW. 3. USE ALT. HOLD DOWN ON NORTH SIDE OF GARAGE DOOR. PAHDS INSTALLED ON OUTSIDE ARE TOO CLOSE TOGETHER. | |
03/17/1998 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | PARTIAL APPROVAL | |
03/16/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. GABLE END CLIPS MISSING (FRONT ) ENTRY AND GARAGE. 2. HEADER TO KING STUD NEEDS TO BE CLIPPED (FRONT). 3. KING STUD AT SILL GARAGE DOOR NEEDS CLIP. 4. RECLIP AT CORNER BAY FRONT. 5. PAHD TOO CLOSE TOGETHER AT GARAGE USE ALTERNATE HOLD DOWNS. | |
03/16/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED |