Permit: T98CM00422

Parcel: 130120830


Addresses:

3733 E ELLINGTON PL

Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/05/2000 BUILDING - FINAL Correction Required ADDTL COMMS - NO ACCESS; NO ONE HOME
05/05/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*
04/28/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*
04/21/2000 BUILDING - FINAL Denied IVRS - Inspection 0920*
04/14/2000 BUILDING - FINAL Correction Required ADDTL COMMS - NOT READY - FROM LAST INSPECTION OF 04-11-00. 1. PROBLEMS WITH CONSTRUCTION OF FIREPLACE. THE PERSON WHO BUILT IT NEEDS TO BE PRESENT AT THE TIME OF INSPECTION. WHAT IS THE FIRE BOX MADE OF? PROBLEMS OF COMBUSTIBLES TOO CLOSE TO THIS FIRE BOX AND CHIMNEY WALLS. HOW WAS IT CONSTRUCTED. 2. 4X4 HEADER IS TOO SMALL. 3. ALL METAL BOXES NEED TO BE BONDED. 4. OLD PORCH LIGHT NEEDS A BOX EXTENSION THAT IS FLUSH WITH THE NEW DRYWALL SURFACE. CANNOT BE COVERED INSIDE THE WALL. SEE ITEM #9. 5. NEED 5 HIGH WATER HEATER FLUE. 6. NEED TEMPORARY PRESSURE RELIEF LINE.
04/14/2000 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
04/11/2000 BUILDING - FINAL Correction Required ADDTL COMMS - DENIED - CORRECT AND RESCHEDULE INSPECTION. 1. NO PLAN ON SITE. YOU MUST HAVE PLAN FOR INSPECTION. 2. WOOD FRAME CANNOT BE WITHIN 2 OF FIREPLACE MASONRY. 3. 4X4 HEADER IS NOT ADEQUATE FOR 5 FOOT SPAN. 4. PROVIDE PROOF OF ADEQUATE 12X 12 FOOTER UNDER BEARING WALLS. 5. METAL ELECTRIC BOXES REQUIRE GROUNDING AND BUSHINGS IN K.O.S. 6. WIRES ARE NOT PROPERLY SECURED. 7. A.B.S. PLASTIC IS NOT ALLOWED ON EXTERIOR OF BUILDINGS. 8. WATER HEATER REQUIRES VENT. MINIMUM 5 FEET HIGH. 9. YOU MUST HAVE AN APPROVED CONSTRUCTION PLAN/DETAILS FOR MASONRY FIREPLACE.
04/11/2000 BUILDING - FINAL Denied IVRS - Inspection 0950*
03/08/2000 BUILDING - FINAL Correction Required ADDTL COMMS - NOT READY - 1. NEED 2 RISER, TRAP, DRAIN, VENT FOR WASHING MACHINE. 2. INSTALL H2.5 RAFTERS TIES TO DOUBLE 2X8 HEADERS. 3. NEED HEADER VERIFICATION OVER EXTERIOR SLIDING GLASS DOOR. 4. NEED SEWER RECEIPT FROM PIMA COUNTY WASTEWATER MANAGEMENT FOR WASHING MACHING HOOK-UP. 5. NEED SMOKE DETECTORS IN ALL BEDROOMS AND HALLWAY LEADING TO BEDROOMS. 6. COMPLETE AND RECALL WHEN READY.
03/08/2000 BUILDING - FINAL Not ready for Inspection NOT READY FOR INSPECTION
06/19/1998 BUILDING - FINAL Correction Required ADDTL COMMS - THE FOLLOWING REQUIRE CORRECTION: 1. THE FIRE PLACE IS NOT A ZERO CLEARANCE MANUFACTURED APPLIANCE. 2. THE FIRE PLACE DOES NOT MEET THE REQUIREMENTS OF THE UNIFORM BUILDING CODE FOR MASONRY BUILT FIRE PACES. 3. THE GAS METER MUST BE RELOCATED. GAS LINES ARE NOT ALLOWED UNDER CONCRETE SLABS. 4. THE CLOTHES WASHING MACHINE IS PLUMBED INTO AN END OF TERMINAL CLEANOUT. YOU WILL NEED TO APPLY TO PIMA COUNTY WASTE WATER FOR A PERMIT TO HOOK UP THE WASHER. YOU WILL ALSO NEED TO HAVE THE PLUMBING CORRECTLY INSTALLED. 5. RAFTER JOISTS MAY NOT BE SEATED ON WALL SUPPORT CHECK AND CORRECT. 6. HEADER OVER SLIDER (SGD) THERE MAY NOT BE ONE.
06/19/1998 BUILDING - FINAL Denied DENIED