Inspection Status: Correction Required
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/29/1998 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - 1. PTR AT WATER HEATER NEEDS TO GO TO DAYLIGHT AND NOT BE CONNECTED TO WASTE LINE. 2. NEED TO HAVE GAS COCK FLEX HOSE ON AND CAPPED AT DRYER. 3. FUSED OUTLET REQUIRED AT FURNACE (SRU). 4. WATER BOND REQUIRED FROM COLD WATER PIPING TO MAIN ELECT PANEL. IF WATER PIPING IS ALL COPPER. IF PLUMBED IN PLASTIC WATER PIPING. WRITE INSIDE MAIN ELECT PANEL PLUMBED IN PLASTIC PIPE. |
| 12/29/1998 |
BUILDING - FINAL |
|
Denied |
DENIED |
| 12/16/1998 |
BUILDING - FINAL |
|
Correction Required |
ADDTL COMMS - INSTALL W/P RECEPTACLE COVER ON PLUG AT SOUTH SIDE AND ADD AN SNTI SIPHON ADAPRTO TO HOSE BIBB ON NORHT SIDE |
| 12/16/1998 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |