Permit: T98BU03033

Parcel: 141150890

Inspection Status: Correction Required

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
01/20/1999 POOL/SPA PRE-GUNITE Correction Required ADDTL COMMS - 1. PROJECT PROCEEDED WITHOUT PRE GUNITE REINSPECTION. 2. OKAY TO BACK FILL TRENCH
01/20/1999 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*
01/15/1999 POOL/SPA PRE-GUNITE Correction Required ADDTL COMMS - CONTRACTOR WANTS TO RUN BOND WIRE FROM EQUIPMENT TO WROUGHT IRON, PLASTIC GAS LINE HAS NO LABELING AT ALL ON PIPE EXTERIOR, ELEC & GAS ARE IN SAME TRENCH AT A DEPTH OF 12 ONLY, PLEASE REVIEW PREVIOUS INSPECTION REPORTS, OBTAIN CERTIFICATION FOR POLY GAS LINE AND CALL DSC TO SPEAK TO MR. DURAZO
01/15/1999 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*
01/06/1999 POOL/SPA PRE-GUNITE Correction Required ADDTL COMMS - 1. YELLOW GAS PIPE IS NOT A CITY APPROVED GAS LINE. 2. GAS, ELECTRIC AND PLUMBING SHOULD BE CALLED IN A GUNITE ALSO. DO NOT BACK FILL TRENCHES.
01/06/1999 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*
12/22/1998 POOL/SPA PRE-GUNITE Correction Required ADDTL COMMS - 1. POOL LAYOUT IS NOT PER PLAN. SEE 12/21/98 INSPECTION ALL STEEL AND BOND WIRE IS OKAY-GUNITE AT YOUR OWN RISK. YOU MUST REVISE SITE PLAN TO AS BUILT. NOTE: DO NOT BACK FILL TRENCHES.
12/22/1998 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*
12/21/1998 POOL/SPA PRE-GUNITE Correction Required ADDTL COMMS - 1. PLAN CALLS FOR POOL TO BE 4 FEET FROM REAR WALL ONLY 3 6 WILL EXIST AT FINISHED POOL. 2. ELECTRIC AND BONDING WIRES NOT INSTALLED. 3. POLYETHYLENE GAS PIPE MUST BE A MINIMUM OF 18 BELOW GRADE TO TOP OF PIPE. 4. BE SURE TO CALL FOR GAS, ELECTRIC, PLUMBING AND PREGUNITE INSPECTION.
12/21/1998 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0805*