Inspection Status: Correction Required
Inspection History: POOL/SPA FINAL/BARRIER
| Date |
Description |
Inspector |
Results |
Comments |
| 06/19/1998 |
POOL/SPA FINAL/BARRIER |
|
Correction Required |
ADDTL COMMS - 1. POOL GATE MUST BE SELF CLOSING AND LATCHING PRESENTLY GATE BINDS ON STRIKER POST. 2. METAL FENCING WITHIN 5 FEET OF POOL MUST BE ELECTRICALLY BONDED TO POOL EQUIPMENT WITH PROPER BONDING CONNECTORS AND MACHINE SCREWS WITH NUTS. DO NOT USE SELF TAPING SCREWS. 3. AN EXCESS OF 4 INCH OPENING EXISTS BETWEEN BOTTOM OF FENCE AND NATURAL GRADE. |
| 06/19/1998 |
POOL/SPA FINAL/BARRIER |
|
Denied |
DENIED |