Permit: T97PL00387

Parcel: 127071530


Addresses:

5224 E ALBERTA DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/11/2007 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
06/26/2007 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
PET. OF APPEAL #33107 OK
1. SECURE VENT CONNECTOR W/GALV SHEETMETAL SCREWS
2. T&P CANNOT BE TRAPPED
06/13/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) EXPLAINED ? OF APP REQUIREMENTS
04/12/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
03/16/2007 PLUMBING - GAS PRESSURE TEST Denied GAS METER IS ON
PROVIDE A PETITION OF APPEAL FORM FOR WATER HEATER
TEMPERATURE & PRESSURE RELIEF DRAIN
INSTALL A DRAIN PAN AND AN EXTERIOR RELIEF VALVE
EXTEND WH & FURNACE VENTS TO ABOVE COOLER
SECURE WH VENT CONNECTOR W/SCREWS.
04/29/1997 PLUMBING - GAS PRESSURE TEST Denied DENIED