Inspection Status: Correction Required
Inspection History: BUILDING W/O PERMITS INSPECTIO
| Date |
Description |
Inspector |
Results |
Comments |
| 10/20/1997 |
BUILDING W/O PERMITS INSPECTIO |
|
Correction Required |
ADDTL COMMS - SCREW OFF EXTERIOR SIDING 6 O.C. EDGES & 12 O.C. FIELD, EXT ELEC RECEPT TO BE GFCI & IN WEATHERPROOF BOX, ADD SMOKE DETECTORS TO BEDROOM, ADD HEAT TO BEDROOM, SHEETROCK ON CEILING CANT SEE RAFTERS - OWNER CLAIMS RAFTERS CLIP TO FASCIA - ROOF HAS BEEN HERE FOR 6 YRS - SHOULD BE OK, 60 AMP PANEL - (1) 30 AMP BREAKER (10) 20 AMP BREAKER (4) 15 AMP BREAKER, WIRE FEEDING PANEL TYPE THW Z1L 600 VOLT, CANT SEE BOTTOM PLATE |
| 10/20/1997 |
BUILDING W/O PERMITS INSPECTIO |
|
Denied |
DENIED |