Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/05/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - THE AIR REGISTER ABOVE DINING AREA HAS NOT BEEN INSTALLED. I ASSUME OWNER BUILDER HAS TAKEN NOTICE ADN ELECTS TO CONTINUE. |
| 03/04/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. THE TJI HANGERS IN THE GARAGE , LIVING ROOM AND OTHER LOCATIONS HAVE NOT BEEN PROPERLY NAILED TO THE BOTTOM CHORD. 2. SOME SHORT INTERIOR PARTITIONS NEED CUT NAILS MARKED W/X. 3. THE BOTTOM PLATE MUST BE REINFORCED ON BOTH SIDES WHERE CUT TO ALLOW PLIMBING PIPES THRU. STRAP MUST BE LONG ENOUGH TO ALLOW 3 10D NAILS ON EACH EDN OF STRAP. SEE UBC2326.11.7. 4. THE SUPPLY AIR DUCT AND REGISTER TO DINING ROOM HAS BEEN OMITTED- INSTALL PER PLAN OR SUBMIT REVISION W/CALCS. 5. OSB PANELS IN CASED OPENING HALL TO LIVING ROOM NEED NAILING. |
| 03/04/1998 |
FRAMING |
|
Denied |
DENIED |