Inspection Status: Correction Required
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/29/1999 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - APPROVE AND OK UG COPPER. WRAP 2 ABS IN FOOTING. |
| 07/26/1999 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - BACK PITCH ON A.B.S. @ 3X2 WY SUPPORT @ REBAR CLOSET BENDS AND TUB TRAP ARMS CHECK ALL PIPING. |
| 07/26/1999 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0000* |
| 07/21/1999 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - 1. DOUBLE WYS NOT ALLOW. HORIZONTAL USE SEPERATE WY-SUBJECT TO FALL 2. USE APPROVE 2 MED SWEEP, REMOVE 2 SHORT 1/4 BENDS 3. LEAK ON 1 1/2 P TRAP @ TUB WESTUNIT 4. BACK FALL ON A.B.S. PIPE, CHECK 2 &3 |
| 07/21/1999 |
PLUMBING - ROUGH, SOIL |
|
Denied |