Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T97CM03736
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/27/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - H2.5 CLIPS ON FRONT TRUSSES AT ENTRY MISSING, CHECK ALL HORIZONTAL JOINTS AT TOP OF SHEAR PANELS FOR NAIL INTO BLOCKING, GROUT UNDER TUB, NO WATER PRESSURE TO PLBG, EXHAUST FAN IN LAUNDRY HANGING - INSTALL PROPERLY | |
01/27/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED | |
01/21/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. SEAL FIRESTOP @ OSB TO WALL @ FIREPLACE. 2. PAHD MISSING @ FRONT BEDRM EACH SIDE OF WINDOW. 3. HAVE CITY APPR FLR PLAN AND FRAMING SPECS IE-SHEAR AND HOLD DOWN FOR EXPANDED MASTBEDRM. | |
01/21/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED | |
12/24/1997 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. NAIL PA STRAPS TO DBL FULL HEIGHT STUDS. 2. CK ALL SHEAR WALLS FOR NAILING- STAPLE MARKS IN OSB BUT NO STAPLES INTO STUDS. CK ALL HORIZ BLOCKING. | |
12/24/1997 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED | |
12/19/1997 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - SEE DETAIL 12-D1 & COMPLY, NAIL ALL EDGES OF SHEAR PANELS, HDS MUST GO TO DOUBLE STUDS NOT TRIMMERS | |
12/19/1997 | EXT METAL CLIPS/EXT SHEATHING | Denied |