Permit: T97CM03736

Parcel: 133530020

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T97CM03736

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
01/27/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - H2.5 CLIPS ON FRONT TRUSSES AT ENTRY MISSING, CHECK ALL HORIZONTAL JOINTS AT TOP OF SHEAR PANELS FOR NAIL INTO BLOCKING, GROUT UNDER TUB, NO WATER PRESSURE TO PLBG, EXHAUST FAN IN LAUNDRY HANGING - INSTALL PROPERLY
01/27/1998 EXT METAL CLIPS/EXT SHEATHING Denied DENIED
01/21/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. SEAL FIRESTOP @ OSB TO WALL @ FIREPLACE. 2. PAHD MISSING @ FRONT BEDRM EACH SIDE OF WINDOW. 3. HAVE CITY APPR FLR PLAN AND FRAMING SPECS IE-SHEAR AND HOLD DOWN FOR EXPANDED MASTBEDRM.
01/21/1998 EXT METAL CLIPS/EXT SHEATHING Denied DENIED
12/24/1997 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 1. NAIL PA STRAPS TO DBL FULL HEIGHT STUDS. 2. CK ALL SHEAR WALLS FOR NAILING- STAPLE MARKS IN OSB BUT NO STAPLES INTO STUDS. CK ALL HORIZ BLOCKING.
12/24/1997 EXT METAL CLIPS/EXT SHEATHING Denied DENIED
12/19/1997 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - SEE DETAIL 12-D1 & COMPLY, NAIL ALL EDGES OF SHEAR PANELS, HDS MUST GO TO DOUBLE STUDS NOT TRIMMERS
12/19/1997 EXT METAL CLIPS/EXT SHEATHING Denied