Permit: T97CM03422

Parcel: 11623192A


Addresses:

932 S KROEGER LN

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
01/12/1999 FRAMING Correction Required ADDTL COMMS - 1. TRUSS REPAIR-NOT NAILED TO PLAN
01/12/1999 FRAMING Denied IVRS - Inspection 0999*
11/27/1998 FRAMING Not ready for Inspection IVRS - Inspection 0000*
10/30/1998 FRAMING Correction Required ADDTL COMMS - 1. NEED TRUSS REPAIR DRAWING FOR TRUSSES THAT HAVE BEEN CUT AT TOP CORDS FROM TRUSS MANUFACTURE AND HAVE CITY APPROVE REPAIR DRAWINGS. 2. INSTALL X BRACING IN TRUSSES AT BOTH ENDS AND MIDDLE. 3. INSTALL LATERAL BRACING ON TRUSS WEBBS PER TRUSS DRAWINGS. 4. BLOCK RIDGE LINE PER PLANS AND INSTALL LATERAL BRACING AT ENDS. 5. TRUSS I.D #4 IS NON STRUCTURAL AND NEEDS CONTINIOUS SUPPORT AT BOTTOM CORD. TRUSS I.D. #1 NEEDS TO HAVE BEARING UNDER STUBBED END. BOTH TRUSSES AT FRONT ENTRY. HAVE TRUSS ENGINEER DESIGN FIX IN THIS AREA. 6. TRUSSES OVER ENTRY DONT HAVE BEARING WALL, NO FOOTINGS AT ENTRY AREA NEED TO REDESIGN.
10/30/1998 FRAMING Denied DENIED