Date Description Inspector Results Comments
12/31/1997 STUCCO MESH Correction Required ADDTL COMMS - 1. SEE DETAIL 8-D01- SWAY BRACING @ 6 OC. 2. GABLE END X BRACING MISSING @ GARAGE- SEE ABOVE ALSO. 3. LADDER BLOCKING @ BEDRM#2/BEDRM#3. WONT WORK FOR SHEAR NAILING. 4. 1 MIN CLEARANCE FROM COMBUSTIBLES @ GAS FLUE. 5. NEED TRUSS CALCS ON SITE. 6. GAS FLUE MISSING @ WH. 7. BLOCKING MISSING FOR SHEAR @ KITCHEN.
12/31/1997 STUCCO MESH Denied DENIED