Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T97CM03174
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/03/1997 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. GASLINES NOT INSTALLED. 2. NO GAS PRESSURE TEST. 3. GARAGE SHEAR WALL 8 REQ 8D NAILS AT 4 OC ON EDGES, STAPLES INSTALLED AT 8-12 OC. 4. #8 SHEAR WALL REQ OSB TRANSFER THRU INTERSECTING GARAGE WALL. PROVIDE ENG APPR REPAIR. 5. HOSE BIB LOOSE AT LAUNDRY. 6. PROVIDE PROOF OF EXT CLIP INSP. TOO MANY ITEMS-STOPPED INSPECTION. | |
12/03/1997 | EXT METAL CLIPS/EXT SHEATHING | Denied | DENIED | |
11/24/1997 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | NO PLANS/PERMIT ON SITE |