Inspection History: FRAMING
Permit Number - T97CM03164
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/31/1997 | FRAMING | Correction Required | ADDTL COMMS - 1. CLIP TOP OF INTERIOR BEARING WALL AND HEADER. 2. A35S INSTALLED WRONG ON LEDGER @ GREAT ROOM- ADD H2.5 TO ALT STUDS. 3. BLOCK STUB TRUSSES ABOVE BEARING WALL. 4. BLOCK AND NAIL SHEAR PANELS @ REAR OF HOUSE. 5. FB @ RANGE HOOD AND ENTERTAINMENT CENTER. 6. PA @ HOUSE FRONT NOT @ DOUBLE STUD. | |
12/31/1997 | FRAMING | Denied | DENIED | |
12/24/1997 | FRAMING | Correction Required | ADDTL COMMS - 1. MISSING OR TIGHTEN RED HEADS BEDRM #2 AND 3. 2. HANGER IN BED #2 HIP. 3. ROOF IS NOT LOADED AND THERE IS NOT ANY CLEARANCE TO WALL BTWN KITCHEN AND GREATRM. | |
12/24/1997 | FRAMING | Denied | DENIED |