Permit: T97CM03148

Parcel: 141182120

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
12/23/1997 FRAMING Correction Required ADDTL COMMS - 1. CONNECTION OF SHEAR TRANSFER BLKS NOT PER PLAN. PLAN CALLS FOR BLOCKS NAILED + STC CLIP ON 2 SIDES @ SHEAR WALL #8 BETWEEN HOUSE AND GARAGE (BOTH WALLS). 2. SHEAR PANEL @ DOOR BTWN HOUSE AND GARAGE RIGHT SIDE IS DAMAGED AT TOP. REPLACE PANEL HAVE ELECTRICIAN DRILL 3/4 MAX HOLES FOR WIRE PENETRATIONS. 3. PATCH LATH, FOAM AND PAPER AT REAR BATH TUB. CAULK ALL PENETRATION THRU LATH AND FOAM ON LAST WALL.
12/23/1997 FRAMING Denied DENIED
12/22/1997 FRAMING Not ready for Inspection NOT READY FOR INSPECTION
12/16/1997 FRAMING Correction Required ADDTL COMMS - SHEAR TRANSFER @ #8 SHEAR WALL MISSING. CK PLATE BOLTS 24 OC MAX. #8 SHEAR WALL @ GARAGE/KITCHEN DOOR MISSING. FLEX NOT CONNECTED TO DISTRIBUTION BOX @ KIT/BEDRM.
12/16/1997 FRAMING Denied DENIED