Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T97CM03133
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/22/1999 | FRAMING | Correction Required | ADDTL COMMS - NEED FIRE BLOCKING-SEE NOTE BELOW 1. FIRE BLOCKING NEEDED ALONG HALL SOFFITT LINE. 2. STRAIGHTEN OUT SOME 2X4 FRAMING WHERE NEEDED. | |
03/22/1999 | FRAMING | Denied | IVRS - Inspection 0999* | |
12/21/1998 | FRAMING | Correction Required | ADDTL COMMS - 1. ROOF FRAMING INCOMPLETE. 2. CLIP INCOMPLETE. 3. INTERIOR WALLS ARE OUT OF PLUMB. 4. SEWER PIPE FROM ROOM ADDITION IS OKAY TO BURY AND BACK FILL. 5. DO NOT CONNECT TO SEWER LINE AT FRONT OF HOUSE WITHOUT FIRST REPLACING THE PVC FITTINGS WITH BLACK ABS PIPE FITTINGS. | |
12/21/1998 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |