Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/18/1997 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. ADD BLOCKS TO AIR REGISTERS HALL BATH & MASTER BATH. 3. ADD ONE ANCHOR BOLT ON GARAGE WAL -NORTH. 3. ADD ONE ANCHOR BOLT ON GARAGE WAL -NORTH. 4. REPLACE NAIL BANG PLATES WITH FHA STRAPS SIZED FOR LENGTH. 5. ADD FHA STRAPS TO TOP PLATES WHERE GAS LINE WAS CUT IN. 6. ADD NAILING TO REAR SHEAR /OSB PANEL. 7. INSTALL WEDGES MISSING ON REAR TRUSS TAILS. 8. INSTALL LTT 7 HTT ANCHORS PER PLAN. 9. INSTALL WALL CLEAN OUTS PER PLUMBING PLAN. |
| 11/18/1997 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |
| 11/06/1997 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |