Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/03/1997 |
FRAMING |
|
Correction Required |
ADDTL COMMS - HOLE CUT IN POST TENSION SLAB BY 3RD BATH WC APPROX 18 AROUND. YOU MUST PROVIDE AN ENG REPORT PRIOR TO FINAL INSP. |
| 12/03/1997 |
FRAMING |
|
Partial Approval |
PARTIAL APPROVAL |
| 12/02/1997 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NO PRIOR INSP RPT ON SITE. 2. PROVIDE CITY APPR ENG RPT FOR POST TENSION SLAB CUT AT WATER CLOSET. 3. TEST CAPS NOT ALLOWED ON DISUSED PLUMBING-INSTALL PERMANENT CAPS. 4. PROTECT PEX FROM SCREW PENETRATIONS AT LAUNDRY. 5. BLOCK DIFFUSERS 3 SIDES. |
| 12/02/1997 |
FRAMING |
|
Denied |
DENIED |
| 12/01/1997 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. BLOCK DIFFUSERS ON 3 SIDES. 2. PROVIDE ENG REPORT FOR CONCRETE REMOVAL AND REPAIR FOR POST TENSION SLAB. DAMAGE AT 3RD BATH. MUST HAVE COT APPR. 3. PROTECT WIRES AT BATH TOP PLATE. 4. TEST PLUGS NOT ALLOWED ON DISUSED PEX. |
| 12/01/1997 |
FRAMING |
|
Denied |
DENIED |