Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
12/03/1997 FRAMING Correction Required ADDTL COMMS - HOLE CUT IN POST TENSION SLAB BY 3RD BATH WC APPROX 18 AROUND. YOU MUST PROVIDE AN ENG REPORT PRIOR TO FINAL INSP.
12/03/1997 FRAMING Partial Approval PARTIAL APPROVAL
12/02/1997 FRAMING Correction Required ADDTL COMMS - 1. NO PRIOR INSP RPT ON SITE. 2. PROVIDE CITY APPR ENG RPT FOR POST TENSION SLAB CUT AT WATER CLOSET. 3. TEST CAPS NOT ALLOWED ON DISUSED PLUMBING-INSTALL PERMANENT CAPS. 4. PROTECT PEX FROM SCREW PENETRATIONS AT LAUNDRY. 5. BLOCK DIFFUSERS 3 SIDES.
12/02/1997 FRAMING Denied DENIED
12/01/1997 FRAMING Correction Required ADDTL COMMS - 1. BLOCK DIFFUSERS ON 3 SIDES. 2. PROVIDE ENG REPORT FOR CONCRETE REMOVAL AND REPAIR FOR POST TENSION SLAB. DAMAGE AT 3RD BATH. MUST HAVE COT APPR. 3. PROTECT WIRES AT BATH TOP PLATE. 4. TEST PLUGS NOT ALLOWED ON DISUSED PEX.
12/01/1997 FRAMING Denied DENIED