Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/14/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - NEED TRUSS SUBMITTAL APPROVED BY ARCHITECT OF RECORD & C.O.T. |
| 12/11/1998 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NEED A.B AT 32 O.C. ON EXT WALLS. 2. NEED SHOES ON INT BEAKING WALLS. 3. NEED TO CUP GLU-LAM DOWN TO DOUBLE TOP PATH AT OUTER WALL. 4. NEED STAIR RISERS COMPLETELY TIED IN AT TOP. 5. NEED APPROVED TRUSS SUBMITALS. 6. MAKE SURE ALL HOLES AND ALL CLIPS FILLED WITH TCO NAILS. 7. CHEKC SHEAR NAILING ON HOUSE (SINGLE STORY UNIT). 8. NEED TRUSS SUBMITTALS ON HOUSE TRUSSES. |
| 12/11/1998 |
FRAMING |
|
Denied |
IVRS - Inspection 0000$ |