Permit: T97CM02678

Parcel: 117022960


Addresses:

921 N 1ST AV #01


Inspection Status: Correction Required

Inspection History: FRAMING

Permit Number - T97CM02678

Inspection Description - FRAMING

Inspection Status - Correction Required

Date Description Inspector Results Comments
12/14/1998 FRAMING Correction Required ADDTL COMMS - NEED TRUSS SUBMITTAL APPROVED BY ARCHITECT OF RECORD & C.O.T.
12/11/1998 FRAMING Correction Required ADDTL COMMS - 1. NEED A.B AT 32 O.C. ON EXT WALLS. 2. NEED SHOES ON INT BEAKING WALLS. 3. NEED TO CUP GLU-LAM DOWN TO DOUBLE TOP PATH AT OUTER WALL. 4. NEED STAIR RISERS COMPLETELY TIED IN AT TOP. 5. NEED APPROVED TRUSS SUBMITALS. 6. MAKE SURE ALL HOLES AND ALL CLIPS FILLED WITH TCO NAILS. 7. CHEKC SHEAR NAILING ON HOUSE (SINGLE STORY UNIT). 8. NEED TRUSS SUBMITTALS ON HOUSE TRUSSES.
12/11/1998 FRAMING Denied IVRS - Inspection 0000$